(changed server version 6.11 or later)
(default = the larger of 60 or (3 * INTERVAL))
CPU-COLLECTOR-NOREPORT-TIMEOUT <seconds>
Specifies the maximum amount of time (in seconds) that MOMI waits for a CPU collector process to report.
A CPU collector process that does not report in a timely manner is stopped and its data cleared. The client initially reports the CPU as HUNG (or STOP). The collector is automatically restarted about 1 minute later.
It is not recommended to increase this value as data reported by the client for that affected processor may be old and incorrect. However, certain system configurations may not be able to provide MOMI the CPU cycles needed to operate timely and this keyword allows for a greater timeout value.
The minimum value allowed is the default. Any value less than the default is set to the default. No maximum is imposed.
This value is not 'exact' and the effective value will usually be higher.
Example:
== set timeout to 30 seconds
CPU-COLLECTOR-NOREPORT-TIMEOUT 30